Model 1100 XY

Model 1100

Boost Productivity With Fast, Reliable Measurement

Unmatched flexibility and precise, high-speed recording offer accuracy and reliability all the way through to completion.

Flexible and Reliable

  • Inch or metric calibration available
  • Wide range of chart sizes are accommodated

Perfect For Filling The Gaps

  • Can be configured to be a form, fit and function replacement of Hewlett Packard’s 7044 and 7045 recorders
  • OEM and HP 7040®/7041® configurations may also be specified.

Fast, Precise, And Built For Your Workflow

HP Interface Option

Simplifies the recording of transducer signals by providing an adjustable excitation voltage of +5 to +15 VDC 50 mA (350 Ohms), which can be tapped from the rear signal input connector or from a terminal strip on models with the HP Interface Option.

Stable, Dependable Operation

Ultra stable IC circuitry requires no additional servo compensation or loop gain adjustments, and servo feedback is provided by optical encolorers.

1100 Series XY Recorders Specs

Model 1144E

Acceleration

Standard, 5G (2000 in/sec/sec)

Sensitivities

0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10, 20 mV and V/inch plus VARIABLE GAIN

Time Based Ranges

0.5, 1, 2, 5, 10, 20, 50, 100, 200, 500, 1000 sec/in

Calibrated Offset - Sensitivity

0.5, 0.1, 0.2, 0.5 mV
1, 2, 5, 10, 20 mV
0.5, 0.1, 0.2, 0.5 V
1, 2, 5, 10, 20 V

Calibrated Offset - Offset

0 to +/- 100 mV
0 to +/- 1000 mV
0 to +/- 100 V
0 to +/- 1000 V*

Model 1144M

Acceleration

Standard, 5G (5080 cm/sec/sec)

Sensitivities

0.025, 0.1, 0.25, 0.5, 1, 2.5, 5, 10, mV/cm and V/cm plus VARIABLE GAIN

Time Based Ranges

0.25, 0.5, 1, 2.5, 5, 10, 25, 50, 100, 250, 500 sec/cm

Calibrated Offset - Sensitivity

0.025, 0.05, 0.01, 0.25 mV
0.5, 1, 2.5, 5, 10 mV
0.025, 0.05, 0.01, 0.25 mV
0.5, 1, 2.5, 5, 10 mV

Calibrated Offset - Offset

0 to +/- 100 mV
0 to +/- 1000 mV
0 to +/- 100 V
0 to +/- 1000 V*

Model 1145E

Acceleration

High, 10G (4000 in/sec/sec)

Sensitivities

0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10, 20 mV and V/inch plus VARIABLE GAIN

Time Based Ranges

0.5, 1, 2, 5, 10, 20, 50, 100, 200, 500, 1000 sec/in

Calibrated Offset - Sensitivity

0.5, 0.1, 0.2, 0.5 mV
1, 2, 5, 10, 20 mV
0.5, 0.1, 0.2, 0.5 V
1, 2, 5, 10, 20 V

Calibrated Offset - Offset

0 to +/- 100 mV
0 to +/- 1000 mV
0 to +/- 100 V
0 to +/- 1000 V*

Model 1145M

Acceleration

High, 10G (10160 cm/sec/sec)

Sensitivities

0.025, 0.1, 0.25, 0.5, 1, 2.5, 5, 10, mV/cm and V/cm plus VARIABLE GAIN

Time Based Ranges

0.25, 0.5, 1, 2.5, 5, 10, 25, 50, 100, 250, 500 sec/cm

Calibrated Offset - Sensitivity

0.025, 0.05, 0.01, 0.25 mV
0.5, 1, 2.5, 5, 10 mV
0.025, 0.05, 0.01, 0.25
mV 0.5, 1, 2.5, 5, 10 mV

Calibrated Offset - Offset

0 to +/- 100 mV
0 to +/- 1000 mV
0 to +/- 100 V
0 to +/- 1000 V*